4 | mechanical extraction resistance test |
| ||
3 | pull out test |
|
mechanical extraction resistance test Explanation: Or physical. Presumably they try to pull it out. |
| |
Login to enter a peer comment (or grade) |
pull out test Explanation: In the French, it is described as "Lors des tests push-out ou tests d’extraction, qui ont pour but de quantifier la résistance mécanique de l’interface os/implant en mesurant la force nécessaire à l’extraction d’un implant, aucune différence n’a pu être faite entre les deux groupes d’implants." https://dumas.ccsd.cnrs.fr/dumas-01452692/file/Chir-dent-201... In English, it is called 'tensile pull out test', 'pull-out test' and 'mechanical testing (pull-out)'. "The purpose of the present study was to evaluate the osseointegration of titanium implants with coin-shaped geometry and different surface roughnesses applying tensile pull out test using sheep as an animal model. MATERIAL AND METHOD: The tensile pull out test was performed with the application of a gradual load perpendicular to the bone-implant interface" "Pull-out tests The measurement of the maximum pull-out force is another parameter that has been used to estimate implant stability, because the pull-out force is directly related to implant loosening. Many studies have been carried out using such an approach for various types of implants, such as hip and knee implants (in cadaveric studies) or dental implants. " "Pull-Out Test After μCT analysis, the implants were subjected to pull-out testing. To this end, the tibiae were held with a metal jig while a metal clasp was affixed to the test implants’ head and was used to grip the implant during pulling. Pull-out strength was determined as the peak force (i.e., the maximum failure force) applied when detaching the implant from the bone. " https://www.researchgate.net/publication/33550850_Osseointeg... https://royalsocietypublishing.org/doi/10.1098/rsif.2019.025... https://www.hindawi.com/journals/bmri/2013/234093/ |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.