GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
16:46 Nov 12, 2020 |
Spanish to English translations [PRO] Tech/Engineering - Architecture / Panamanian Spanish | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Taña Dalglish Jamaica Local time: 09:16 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
3 | moment-resisting frame |
| ||
2 +1 | moment frame (building) |
|
Discussion entries: 2 | |
---|---|
moment-resisting frame Explanation: Moment-resisting frame is a rectilinear assemblage of beams and columns, with the beams rigidly connected to the columns. https://en.wikipedia.org/wiki/Moment-resisting_frame "In moment resisting frames, the structural members are joined together using rigid joints which transfer moment. So, the moment resisting frame depends on the joints to transfer lateral loads to the foundation." https://theconstructor.org/structural-engg/braced-frame-vs-m... |
| |
Login to enter a peer comment (or grade) |
moment frame (building) Explanation: ... 6-story (storey Br. English) concrete, moment frame building, reinforced slabs. http://www.cenapred.gob.mx/es/Publicaciones/archivos/187-CUR... 0_3er-tea/fa F114 DIRECT - Centro Nacional de Prevención ...www.cenapred.gob.mx › Publicaciones › archivos › 187-...PDF r.NaA..taN 1. ,^. PLACA DEL. PACIFICO. DEDD. P(Au^. ^. Feo 6 w..u NIRrNN ... Structures (Comprehensive Project on New Advanced Materials) Part 20. ... En estructuras a base de marco momento resistentes, los elementos columna en la ... American Concrete Institute, "Building Code Requirements for Reinforced Conc ... En estructuras a base de **marco momento resistentes**, los elementos columna en la mayoría de los casos estarán sujetos a carga axial y momento flexionante (uniaxial y biaxial). Page 246- HOUSING REPORT Reinforced Concrete Moment Frame ...www.world-housing.net › WHEReports https://www.world-housing.net/WHEReports/wh100108.pdf Sep 14, 2004 — Housing Sub-Type RC **Moment Frame Building** : Designed for gravity loads ... captive column failure; punching shear failures in flat plate slabs; and shear and axial load ... earthquake, the 6 story reinforced concrete Imperial. Seismic Design of Reinforced Concrete Special Moment Frames www.atcouncil.org › pdfs › nistgcr8-917-1 ... arising from such use. Cover photo – Reinforced concrete special moment frame under construction. ... provisions for special moment frames exclude use of slab- ... Special moment frames with story heights up to 20 feet are not uncommon. ... seismic load, amplified by Cd (ASCE 7 - 12.8.6), when comparing it with the ... https://www.researchgate.net/publication/268589860_Design_an... In addition, a full-scale five-story steel** moment frame building ** tested at E-Defense was outfitted with interior walls, ceilings, piping, and concrete cladding panels. This test focused on displaying the effectiveness of using friction pendulum isolators to protect the structure and its contents during extreme ground shaking (Dao et al., 2011). -------------------------------------------------- Note added at 3 days 21 hrs (2020-11-16 14:00:40 GMT) Post-grading -------------------------------------------------- Thank you. |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.